Energinet Gastransmission A/S har brug for isolerende koblinger til fire stationer: Køge, Herning, Nørskov og Frøslev. Kontrakten har en varighed på 1 år og en forventet værdi på 800.000 Euro. Leverandøren skal levere isolerende koblinger, og der lægges vægt på teknisk løsning, herunder dokumentation af tests, typegodkendelser og certificeringer, samt kvalitetssikring og kvalitetskontrolsystemer. Tildelingskriterierne er pris (20%), teknisk løsning (40%) og kvalitetssikring og kvalitetskontrol (40%). Kvalifikationskrav inkluderer referencer på specificerede arbejder.
Slipp å lese og skrive alt selv, la Cobrief gjøre det for deg!
Prøv Cobrief ProOm anbudet
- Kontakt navn
- Anja Lorenzen
- Kontakt telefon
- 70102244
- Kontakt e-post
- ANL@energinet.dk
- Adresse
- Tonne Kjærsvej 65, 7000 Fredericia
The Contracting Authority wants to purchase insulating couplings for 4 stations: Køge, Herning, Nørskov and Frøslev. For further details regarding the purchase, reference is made to the tender documents. The tendered contract has a duration of 1 year. The value of the contract is expected to amount to 800,000 Euro For further details concerning the purchase, reference is made to the tender documents.
Kvalifikasjonskrav
Tildelingskriterier
Beskrivelse
Prices must be stated in the attached Price List, and the defined price elements must be completed herein. Prices must be stated exclusive of VAT but inclusive of all other expenses associated with the purchase. Prices must be stated in Euro.
Evalueringsmetode
When evaluating 'Price', the Contracting Authority will evaluate the total cost (for evaluation purpose), cf. the Price List.
Beskrivelse
The tenderer must as part of the sub-criterion “Technical solution description” also include the following: * The tenderer shall always comply with all points specified by Energinet in the datasheets. But the tenderer shall state explicitly every point where the products do not conform to the datasheets. * The tenderer must state following criteria in the documents for all insulation couplings/joints: maximum allowable stress value (min SMYS), design factors, bending moment, corrosion allowance, production allowance and axial force. Furthermore, the tenderer must document all tests to be performed according to the specification e.g. impact tests. * Installation- and service manuals for the insulating couplings/-joints shall be provided in the documents submitted with the tender.
Evalueringsmetode
When evaluating 'Technical solution description', the Contracting Authority will evaluate the degree to which the tender demonstrates a solution that is supported by tests, type approvals, and certifications. In this context, the elements listed below are of particular importance: * Process data, design data and certifications * Any deviations may lead to a reduction to the score depending on the content, clarity, and consequence. It is explicitly noted that deviations to the sections in the datasheets regarding process data, design data and certifications will be of importance in the evaluation. An overall evaluation will be made of this sub-criterion.
Beskrivelse
The tenderer must as part of the sub-criterion 'Quality assurance and quality control' include the following: * A detailed description of the specific quality assurance and quality control performed for the products which will be delivered to the Contracting Authority, including QA plan, inspection, and test plan. * A detailed description on how certified quality management systems are used to support quality assurance and quality control when producing to the Contracting Authority (API, ISO or equivalent).
Evalueringsmetode
When evaluating 'Quality Assurance and Quality Control', the Contracting Authority will evaluate to which degree the tenderer provides assurance for the quality of the components delivered to the Contracting Authority. In the evaluation of 'Quality Assurance and Quality Control', the Contracting Authority will emphasize the following as positive: * QA plan: If the QA plan includes documentation of quality assurance measurements and controls implemented at every stage of the design and manufacturing processes. * Test plan: If the test plan specifies the testing methodologies, standards, and acceptance criteria to validate the tendered product's quality. * Final documentation and inspection: If there is documentation of final testing and inspection. An overall evaluation will be made of this sub-criterion.
Se hele utlysningen
- Innkjøper
- Tittel
- Procurement of insulating couplings
- Hovedkode
- Tilleggskoder
- Lokasjon
- Estimert verdi
- 800 000,00 €
- Varighet
- 1 år
Ingen tilleggskoder fra innkjøper …