Utgått

Konkurransen er utgått uten at vinner er annonsert.

Brief

Medisinsk og laboratorieutstyr

UiT The Arctic University of Norway wishes to procure a neuronavigated TMS robotic system: the Localite-Axilum-MagVenture Ultimate TMS Solution. The equipment will be used for research at the Department of Psychology, Faculty of Health Sciences. The system will be employed for both basic neuroscience research and clinical research applications. 1.1 System Components The complete system shall comprise the following integrated components: MagVenture TMS Stimulator System • MagPro X100 TMS stimulator • Appropriate coils/coil holders for both cobot-guided and manual stimulation studies • Chair/trolley as appropriate for TMS studies using the cobot Axilum Robotics TMS-Cobot System • Axilum Robotics TMS-Cobot 2 • TMS-Cobot Coil adaptation kits for relevant coils Localite Neuronavigation System • Localite TMS Navigator Premium Edition with Extended Volume • appropriate extension kits for use with the Cobot 1.2 Technical Requirements The integrated system must meet the following technical specifications: • Spatial accuracy: Millimeter-level precision (≤1 mm) for coil positioning • Automated repositioning: Fast and programmable switching of stimulation locations (on the order of a few seconds) • Programmable control: Full software control of stimulation sequences and target locations • MRI integration: Capability to import and use individual MRI data for neuronavigation • Real-time tracking: Continuous monitoring of coil position relative to target • Full system integration: Seamless communication between robot, neuronavigation, and TMS stimulator for closed-loop protocols

Slipp å lese og skrive alt selv, la Cobrief gjøre det for deg!

Prøv Cobrief Pro

Resultat

Vinner
Magventure A/S
Antall mottatte tilbud
0
Kontraktsverdi
331 000 €

Om anbudet

    UiT The Arctic University of Norway wishes to procure a neuronavigated TMS robotic system: the Localite-Axilum-MagVenture Ultimate TMS Solution. The equipment will be used for research at the Department of Psychology, Faculty of Health Sciences. The system will be employed for both basic neuroscience research and clinical research applications. 1.1 System Components The complete system shall comprise the following integrated components: MagVenture TMS Stimulator System • MagPro X100 TMS stimulator • Appropriate coils/coil holders for both cobot-guided and manual stimulation studies • Chair/trolley as appropriate for TMS studies using the cobot Axilum Robotics TMS-Cobot System • Axilum Robotics TMS-Cobot 2 • TMS-Cobot Coil adaptation kits for relevant coils Localite Neuronavigation System • Localite TMS Navigator Premium Edition with Extended Volume • appropriate extension kits for use with the Cobot 1.2 Technical Requirements The integrated system must meet the following technical specifications: • Spatial accuracy: Millimeter-level precision (≤1 mm) for coil positioning • Automated repositioning: Fast and programmable switching of stimulation locations (on the order of a few seconds) • Programmable control: Full software control of stimulation sequences and target locations • MRI integration: Capability to import and use individual MRI data for neuronavigation • Real-time tracking: Continuous monitoring of coil position relative to target • Full system integration: Seamless communication between robot, neuronavigation, and TMS stimulator for closed-loop protocols

    Kontakt navn
    Ana-Maria Virtosu
    Kontakt telefon
    +47 77 64 40 00
    Adresse
    Postboks 6050 Langnes, 9037 Tromsø

Kvalifikasjonskrav

Se konkurransedokumentene for kvalifikasjonskrav

Tildelingskriterier

Se konkurransedokumentene for tildelingskriterier

Tidslinje